# Research sources and claim map

Verified 2 November 2026. Primary studies, manufacturer documentation and reviews serve different purposes below. None is evidence of SeizeFreeze organoid testing or of the reported bench assembly's performance. No experimental result or literature coefficient is silently imported into the new solver. Full text was not available for every source; the verification depth is explicit.

| Source and type | System, observation or scope | Supported use in this experience | Verification and limit |
| --- | --- | --- | --- |
| **Yang, Duffy, Morley and Rothman (2002).** *Neocortical Seizure Termination by Focal Cooling: Temperature Dependence and Automated Seizure Detection.* Epilepsia 43:240–245. [DOI 10.1046/j.1528-1157.2002.33301.x](https://doi.org/10.1046/j.1528-1157.2002.33301.x); [PMID 11906508](https://pubmed.ncbi.nlm.nih.gov/11906508/). Primary experiment. | Halothane-anesthetized rats with experimentally induced focal neocortical seizures; Peltier cooling over dura, temperature and EEG observations, seizure-duration endpoint and automated triggering. | Biological rationale for studying cooling and the importance of spatial/temporal delivery. | Publisher/PubMed record and abstract verified. Not organoid work, a SeizeFreeze test or a source of human thermal limits. The website does not reproduce its biological perturbation method. |
| **Moore, King, Da Silva, Howarth, Berwick, Paterson and Minev (2026).** *Printing-Assisted Integration of Thermal, Fluidic and Electrical Components in Implants for Focal Brain Cooling.* Advanced Science, e77831. [DOI 10.1002/advs.77831](https://doi.org/10.1002/advs.77831); [PMID 42801592](https://pubmed.ncbi.nlm.nih.gov/42801592/); [authors' university repository](https://eprints.whiterose.ac.uk/id/eprint/245376/). Primary experiment. | Printed silicone packages integrate thermal actuation and ECoG with an auxiliary driver; a rodent induced-seizure-like-activity model assesses ECoG spectral power and depth-recorded activity. Reported amplitude/power suppression must not be equated with improvement in every event-rate metric. | Contemporary external precedent for integrated thermal/recording engineering. | Metadata/abstract and public publisher discussion verified; online publication 27 September 2026. Quantitative performance values are not used to calibrate SeizeFreeze. No collaboration or device validation is implied. |
| **Pan, Jaklic, Vaid, Lin, VanHeyningen and Dang (2024).** *A Multi-Electrode Array Platform for Modeling Epilepsy Using Human Pluripotent Stem Cell-Derived Brain Assembloids.* Journal of Visualized Experiments, issue 211. [DOI 10.3791/67396](https://doi.org/10.3791/67396); [PMID 39400160](https://pubmed.ncbi.nlm.nih.gov/39400160/); [author manuscript](https://pmc.ncbi.nlm.nih.gov/articles/PMC11730284/). Primary methods/research article. | Dorsal/ventral fused human stem-cell-derived neural assembloids; extracellular MEA recording of electrical fields/spikes and longitudinal network activity. Coupling/attachment is an identified measurement challenge. | Demonstrates a preparation-specific extracellular recording platform and motivates explicit acquisition/coupling questions. | Author-manuscript abstract and publisher metadata verified; published 27 September 2024. It does not investigate SeizeFreeze cooling, consumer scalp electronics or clinical efficacy. No culturing/plating instructions are reproduced here. |
| **Walker and Parent (2026).** *Modeling Epilepsies with Human Brain Organoids: Recent Advances and Ongoing Challenges.* Epilepsy Currents. [DOI 10.1177/15357597261469411](https://doi.org/10.1177/15357597261469411); [PMID 42528983](https://pubmed.ncbi.nlm.nih.gov/42528983/); [publisher](https://journals.sagepub.com/doi/full/10.1177/15357597261469411). Review. | Surveys organoid/assembloid disease modeling, functional phenotypes, variability, maturation and missing biological context. | Grounds the distinction between a developmental in-vitro model and adult cortical/clinical inference. | Metadata and relevant review text verified; online 28 July 2026. This is synthesis, not a new SeizeFreeze experiment or validation dataset. |
| **Cynthia Lo, Ferdi Ridvan Kiral and In-Hyun Park (2026).** *Functional readouts of neural organoids.* Nature Reviews Bioengineering. [DOI 10.1038/s44222-026-00507-6](https://doi.org/10.1038/s44222-026-00507-6); [publisher](https://www.nature.com/articles/s44222-026-00507-6). Review. | Surveys calcium/voltage imaging, patch clamp, MEAs, functional features and assay comparability. | Supports choosing a functional modality rather than treating all “neural signals” as equivalent. | Published **2 November 2026**. Publisher metadata/abstract and public headings verified; full review text access-restricted. No detailed performance claim is attributed to inaccessible text. |
| **Samarasinghe et al. (2021).** *Identification of neural oscillations and epileptiform changes in human brain organoids.* Nature Neuroscience 24:1488–1500. [DOI 10.1038/s41593-021-00906-5](https://doi.org/10.1038/s41593-021-00906-5); [PMID 34426698](https://pubmed.ncbi.nlm.nih.gov/34426698/). Primary research. | Human regionally specified neural organoid/assembloid systems and disease-associated network phenotypes. | External precedent for interrogating network activity in defined human in-vitro models. | Bibliographic identity verified. No quantitative endpoint is imported here; not evidence of cooling efficacy or SeizeFreeze performance. |
| **Buzsáki, Anastassiou and Koch (2012).** *The origin of extracellular fields and currents—EEG, ECoG, LFP and spikes.* Nature Reviews Neuroscience 13:407–420. [DOI 10.1038/nrn3241](https://doi.org/10.1038/nrn3241); [open author manuscript](https://pmc.ncbi.nlm.nih.gov/articles/PMC4907333/). Review. | Explains extracellular potential relative to a reference, population contributions, recording geometry and interpretation. | Supports distinguishing scalp EEG, cortical surface recording and local extracellular signals. | Public text verified. A field potential is not a direct inventory of individual neuronal activity; this source does not specify the salvaged hardware. |
| **Hamill, Marty, Neher, Sakmann and Sigworth (1981).** *Improved patch-clamp techniques for high-resolution current recording from cells and cell-free membrane patches.* Pflügers Archiv 391:85–100. [DOI 10.1007/BF00656997](https://doi.org/10.1007/BF00656997). Primary instrumentation paper. | Cell/membrane electrophysiology with a dedicated recording arrangement. | Distinguishes intracellular/membrane measurement from extracellular EEG/MEA. | Bibliographic record and public author-paper abstract verified. No experimental instructions are included. |
| **Puppo et al. (2021).** *All-Optical Electrophysiology in hiPSC-Derived Neurons With Synthetic Voltage Sensors.* Frontiers in Cellular Neuroscience 15:671549. [DOI 10.3389/fncel.2021.671549](https://doi.org/10.3389/fncel.2021.671549); [PMID 34122014](https://pubmed.ncbi.nlm.nih.gov/34122014/). Primary research. | Voltage imaging in human induced-pluripotent-stem-cell-derived neuronal cultures; optical readout is tied to a specified sensor/imaging system. | Shows why an optical voltage readout is an instrumented modality, not interchangeable with an electrical trace. | Abstract and public text verified. This is neuronal-culture work, not proof of a SeizeFreeze organoid assay; procedures and illumination settings are not reproduced. |

## Official hardware and physical-model sources

| Source | Supported fact | Boundary |
| --- | --- | --- |
| [NeuroSky ThinkGear overview](https://developer.neurosky.com/docs/doku.php?id=what_is_thinkgear) | Forehead sensing, ear reference/contact, onboard processing and output categories. | Product-family description; does not identify the salvaged board. |
| [NeuroSky EEG Biosensor/TGAT1/TGAM1 page](https://neurosky.com/neurosky-products/eeg-biosensor/) | Lists 3–100 Hz frequency range and 512 samples/s for the documented product family. | Does not establish the reported prototype's passband, output mode or recording quality. |
| [NeuroSky ThinkGear communications protocol](https://developer.neurosky.com/docs/doku.php?id=thinkgear_communications_protocol) | Raw sample formats, model-dependent output rates/ranges, serial data and signal-quality categories. | Model-specific identification/configuration is required; raw counts are not automatically µV. |
| [NeuroSky SDK reference](https://developer.neurosky.com/docs/doku.php?id=thinkgear.net_sdk_dev_guide_and_api_reference) | Explicitly states raw rate, range and conversion depend on hardware characteristics. | Proprietary eSense outputs are not validated seizure labels. |
| [Ferrotec technical reference §2](https://thermal.ferrotec.com/technology/thermoelectric-reference-guide/thermalref02/), [§5](https://thermal.ferrotec.com/technology/thermoelectric-reference-guide/thermalref05/), [§11](https://thermal.ferrotec.com/technology/thermoelectric-reference-guide/thermalref11/) | Electrical-series/thermal-parallel TEC construction, finite heat-rejection need, Kelvin thermoelectric equations and `Qh = Qc + P`. | Sources support equation structure, not the assumed coefficients or measured SeizeFreeze performance. |
| [Pennes (1948)](https://doi.org/10.1152/jappl.1948.1.2.93) | Historical perfusion-exchange framework underlying the existing cortical model. | The original system was a resting human forearm. **No Pennes perfusion term is transferred into the nonperfused sphere model.** |

## Evidence classification and unresolved source needs

- **Established physical relation:** conservative conduction/storage and a stated TEC approximation. Equation correctness is separate from coefficient calibration.
- **External biological result:** belongs to its named authors, preparation, instrument and endpoint. None is a project measurement.
- **Project-specific software result:** comes from the saved parameters, version, seed and numerical solver. It is a simulation.
- **User-reported hardware:** the reported Arduino/Peltier/NeuroSky assembly; exact identity and functional behavior remain unverified.
- **Hypothesis/proposal:** organoid cooling research, additional instrumentation, and future validation milestones.

Needed before expansion: exact hardware records; authorized raw thermal/acquisition data; sensor and electrical calibration; model-specific material/contact measurements; appropriate acquisition requirements; and a separately reviewed biological hypothesis/assay. No supplied DOI/PMID above remains unidentified after verification, but full-text access and verification depth remain limited as stated. Bibliographic verification is not independent experimental validation. Publication dates reflect the records inspected on 2 November 2026; scientific knowledge can advance after this review.